    Data Center Map

    VAZATA Dallas II


    » Index » USA » Texas » Dallas » VAZATA Dallas II

    VAZATA Dallas II is located in the area Dallas, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 14-01-2015.


    Address:
    VAZATA
    2440 Marsh Lane
    75007 Carrollton
    Texas, USA

    » Request quote
    » Visit website

    Click here to find other data centers
    owned and operated by VAZATA.


    Profile
    Tenants
    Connectivity
    Request quote
    Office space
    Rack Cabinets
    Dedicated Servers
    Suites
    Footprints
    Virtual Servers
    Cages
    Hosting of individual servers
    Remote Hands

    Profile


    BUILDING SPECIFICATIONS
    . Features 12,500 of move-in-ready Tier III (with Tier IV attributes) data center space
    . The building is strategically located outside of the 500 year flood plain
    . Facility has diverse and redundant utility feeds, and has diverse entry points for fiber to the facility

    SECURITY
    . Facility is enclosed by vehicle barrier fencing
    . VAZATA provides 24 X 7 days a week on-site uniformed security, including man cage at main entry
    . Cage access is controlled by biometric and/or key card access readers
    . Each VAZATA data center has a minimum of four security checkpoints that are keycard and/or biometric access controlled
    . All access points, common areas and the building perimeter are monitored by CCTV at the data center security station and remotely at a NOC facility
    . Security images are maintained in accordance with PCI requirements
    . The generator yard is located behind a retaining wall around the perimeter for security

    DATACENTER FLOOR
    . 12,500 of move-in-ready Tier III (with Tier IV attributes) data center space . 36-inch raised floor
    . Secure cages and lockable cabinets solutions

    ELECTRICAL POWER
    . The space offers a total capacity of 2.0 Megawatts of power
    . UPS and PDU to the floor configured 2N
    . Power is served by N+1 utility with three diverse paths to the facility
    . True A/B power is delivered to the data center floor with redundant PDU's and PPs
    . Power is monitored to the branch circuit level
    . Generators are configured N+1 with additional roll-up capability
    . The generator yard is located behind a retaining wall around the perimeter for security
    . Generators are tested on a weekly basis
    . VAZATA provides redundant refueling contracts for the data center

    COOLING
    . Dedicated 2N air-cooled chillers, bi-directional chilled water loop with 2N pumping and N+15% CRAH units to each 1125 kW data center
    . Double-interlock, dry pipe, pre-action, water sprinkler system. Overhead and under floor smoke detection

    TELECOM & CONNECTIVITY
    . Fiber enters the building through two separate entrance facilities on different sides of the facility
    . VAZATA has a private, DWDM fully redundant carrier grade fiber ring to connect VAZATA data centers to major carrier hotels

    CARRIERS
    . ABOVENET (ZAYO)
    . TW TELECOM
    . ATT
    . VERIZON


    VAZATA Dallas II Pricing/Quotes


    If you are interested in receiving a quote for VAZATA, please try our free quote service.